Dissolved Oxygen
Related Products
ZÜLLIG
D.O. Probe
with exposed grindstone and electrodes
click
for a larger view

|
B-Line Controller
click
for a larger view

|
ZÜLLIG
Dissolved Oxygen Probe
The
ZÜLLIG D.O. sensor is a precision probe which provides fast
and accurate D.O. control for the needs of a modern process control
application. It operates without a membrane, which eliminates time
delays and wasted aeration costs caused by membrane fouling effects.
Even fats and oils do not limit its use. It uses a diamond grindstone
to continuously clean the heavy duty anode and cathode. Maintenance
is limited to very occasional adjustments to electrode tension,
reducing maintenance and drift. Mounting is normally at depth rather
than on the surface to ensure the most representative reading. Customers
consistently report faster more accurate control of D.O. with lower
O2/kg BOD removed and better plant performance.

Specifications
|
Measuring Range |
Iron
anode; 0 to 15 mg/L
Zinc anode; 0
to 25 mg/L |
|
Temperature Range |
0 to 45 oC |
|
Mains Power |
230 VAC;
+10/-15% |
|
Analog Outputs |
Current (0/4 to 20 mA) |
| Housing |
IP66 |
| Displayed
Variables |
DO (mg/L); Temperature
(oC);
%Saturation |
| Alarm |
Potential free relay contact |
| 2
Limit Contacts |
Potential free relay contact |
|
Computer Interface |
RS 232 or RS 485 |
| Optimal
Controller |
B-Line |

Dimensions
|
DISSOLVED
OXYGEN PROBE
click for a larger view

|

Dissolved
Oxygen Graph from IDEA STP (showing
3 consecutive days)


Application
Papers
Superior
DO Control with Zullig Probes Reduces Aeration Costs at STP's
Excellent
aeration control is essential for the efficient operation of a modern
Sewage Treatment Plant (STP).
The
real cost of inaccurate and varying DO measurement includes :
- wasted aeration power
- reduced nutrient removal efficiency
- poor effluent quality
- possible excessive chemical use for pH
and P removal
Read more...
Simple
Method for the Demonstation of DO Membrane Fouling and it's Impact
on STP's
Fouling
of membranes in Membrane D.O. probes can be demonstrated using a
simple test. A D.O. sensor that reads low is likely to
cause over aeration of the wastewater and cost money.
Read
more...
Success
Story from Australia
Dissolved
Oxygen Control in Industrial Waste Water Treatment. The cost
of buying the Züllig sensors was paid back in 10 weeks...
Read
more...
Advanced
Optimization of Biological Nutrient Removal Plants Using Feedforward
and Feedback Control - Case Studies
The
performance of a wastewater treatment plant can be improved quite
easily. Using advanced process control techniques, processes
are improved and contentration of discharged components decreased.
Read
more...


| |
oxi::lyser
|
| |
con::stat
|
The
s::can oxi::lyser - Optical Oxigen - Plug & Measure
Applications
for Waste Water
- Industrial Waste Monitoring (influent,
aeration tank, effluent)
- Providing measurement in concentrated
industrial waste through to final effluent mf/RO applications
- Inlet load monitoring to indutrial and
municipal WWTP's
- Feed forward control of chemical dosing
to DAF and other treatment processes
- Control of carbon dosing and denitrification
systems
- Monitoring for compliance of discharges
to the environment.

Features
- Plug & Measure
- Long-Term-Stability
- Works-Calibrated
- In-situ & online monitoring
- Automatic cleaning device using compressed
air
- Almost zero maintenance
- No flow rate required
- Requires no chemicals
- Portable
- On board data logging
- Simple data transfer to Excel
- Auto compensation: Temperature

Specifications
| oxi::lyser |
| Measuring
principle |
Fluorescence quenching |
| Measuring
range |
0.0 to 25.0 ppm |
Sensor
cable
|
4 conductor, 22 AWG, Polyurethane jacket |
| Dimensions
|
48mm x 150mm |
Weight
|
appr. 350g w/o cable |
| Response
time |
1 minute |
| Ambient
conditions |
0 - 60'C, 6 bar pressure |
| con::stat |
| Display
|
Full
colour back-lit touch-screen display of current values, spectral
fingerprint and historic trends |
| Signal
Output-expandable |
1.
Four analog outputs
2. Six digital
outputs
3. Analog
and digital input
4. RS 485
TCP/IP RS232 as required |
| Range
|
1.
<0.1 mg/l to 260 mg/l Nitrate as N
2. DOC levels
from ppb to 10,000mg/l COD
3. 0.001 equiv
FTU to 5000 mg/l solids via variable path length modules |
| Supply
voltage |
230V
AC or 10 - 30V DC at 50 watts maximum
Note:
integral user selectable timed sleep mode |
| Housing |
IP65 |

Installation
Options
- Bypass
- Pipe
- Channel
- Tank
- In-bore
- Submerged
- Sewer

Application
Papers
|